# Immich
## VectorCord upgrades
After upgrading the VectorCord extension in the cnpg cluster, reindexing is required. See <https://docs.immich.app/administration/postgres-standalone#updating-vectorchord>.
```sql
ALTER EXTENSION vchord UPDATE;
REINDEX INDEX face_index;
REINDEX INDEX clip_index;
```
Using the cluster's pgadmin deployment is a good way to do this.

View file

@ -0,0 +1,83 @@
# Talos Node Drive Replacement Checklist (with Rook/Ceph)
## Before Starting
- [ ] Identify which nodes are running mons:
```bash
kubectl rook-ceph ceph mon dump
```
- [ ] Verify cluster is healthy:
```bash
kubectl rook-ceph ceph status
```
- [ ] Set noout to prevent OSD rebalancing:
```bash
kubectl rook-ceph ceph osd set noout
```
---
## Per-Node Procedure
Repeat for each node, one at a time.
### 1. Pre-replacement
- [ ] If node has a mon, remove it first:
```bash
kubectl rook-ceph ceph mon remove <mon-id>
```
- [ ] Verify quorum (need 2/3 mons healthy):
```bash
kubectl rook-ceph ceph status
```
### 2. Replace drive
- [ ] Physically replace the drive
- [ ] Reapply Talos config to the node
- [ ] Wait for node to boot and rejoin the cluster
### 3. Post-replacement
- [ ] Verify node is Ready:
```bash
kubectl get nodes
```
- [ ] Wait for OSD to rejoin (if applicable):
```bash
kubectl rook-ceph ceph osd tree
```
- [ ] Wait for mon to be redeployed (if applicable):
```bash
kubectl rook-ceph ceph status
```
- [ ] Confirm 3 mons in quorum before proceeding to next node
- [ ] Wait 10-15 minutes for full stabilization
---
## After All Nodes Complete
- [ ] Unset noout:
```bash
kubectl rook-ceph ceph osd unset noout
```
- [ ] Final health check:
```bash
kubectl rook-ceph ceph status
```
- [ ] Verify all OSDs are up:
```bash
kubectl rook-ceph ceph osd tree
```
---
## Important Reminders
- Always maintain quorum: 2 out of 3 mons must be up
- Do not rush — wait for each node to fully stabilize
- Start with the non-mon node if you want an easy warmup
- OSD data lives on the separate disk, it will rejoin automatically